Labyrinth Weir
    • 21 Sep 2022
    • 7 Minutes to read
    • Dark
      Light

    Labyrinth Weir

    • Dark
      Light

    Article Summary

    A labyrinth weir is a structure designed to convey large flows at low heads by increasing the effective length of the weir crest with respect to the channel breadth. Although generally less efficient than other weir types of the same effective length, the available increase in weir length more than compensates for this.

    Data

    Name

    Description

    Default

    Type

    Constraints

    Required?

    Label1

    Upstream node label

    -

    Character(12)

    Max. 12 characters, no internal or leading spaces

    YES

    Label2

    Downstream node label

    -

    Character(12)

    Max. 12 characters, no internal or leading spaces

    YES

    Label3

    Upstream remote node label (used if upstream node is not a channel section)

    [Label1]

    Character(12)

    Max. 12 characters, no internal or leading spaces

    NO[1]

    Label4

    Downstream remote node label (used if upstream node is not a channel section)

    [Label2]

    Character(12)

    Max. 12 characters, no internal or leading spaces

    NO [1]

    P1

    Weir crest height above upstream bed (m)

    0

    Real

    >0

    YES

    Labyrinth angle (alpha)

    Labyrinth angle (degrees). Angle made by the labyrinth slope with the direction of flow, i.e. 90˚ being a linear weir.

    -

    Real

    ≥6

    YES

    Breadth of channel (W)

    Breadth of weir normal to direction of flow, i.e. breadth of channel (m)

    -

    Real

    >0

    YES

    Number of cycles (N)

    Number of labyrinth cycles

    0

    Real

    >0. NB Can be non-integer, but usually a an integer, or half-integer

    YES

    Length of weir (B)

    Length of weir in direction of flow (m)

    0

    Real

    >0 (if used)

    NO [2],[3]

    Width of apex interior (A)

    Breadth of interior of labyrinth apex (m).

    0

    Real

    ≥0 (if used)

    NO[2],[4]

    Thickness of weir (t)

    Thickness of weir, i.e. distance between upstream and downstream "face" (m).

    0

    Real

    ≥0 (if used)

    NO[2]

    Crest Level (Zc)

    Elevation of crest (m above datum).

    -

    Real

    >-9999.99

    YES

    Effective length of labyrinth (L)

    Effective length of labyrinth, i.e. total length traversed along the weir crest (m).

    -

    Real

    >0

    NO[5]

    Calibration coefficient (Ccf)

    Calibration coefficient

    1

    Real 

    >0

    YES 

    Modular limit (m)

    Modular limit. If set to zero, Villemonte formulation is used for drowned flow.

    0

    Real

    0≤m<1

    YES

    Limit of cd (cdlim)

    Lower limit of discharge coefficient. If set, cd will approach this value as h gets larger; otherwise, the limiting value is L sinα

    0

    Real

     

     

    Length of labyrinth slope (L1)

    Length of single labyrinth arm, i.e. distance along crest of a single (slanted) arm of the labyrinth (m)

    -

    Real

    >0 (if used)

    NO [2],[3]

    Width of apex exterior (D)

    Breadth of exterior of labyrinth apex (m)

    0

    Real

    ≥0 (if used)

    NO [2],[4]

    Use static head (shflag)

    If checked (shflag='STATIC'), the weir equation uses static head for h; otherwise it uses total head.

    Blank

    Character

    'STATIC' is the only valid alternative value; anything else is treated as default (use total head).

    NO

    Theory and Guidance

    Introduction

    A labyrinth weir is a structure designed to convey large flows at low heads by increasing the effective length of the weir crest with respect to the channel breadth. Although generally less efficient than other weir types of the same effective length, the available increase in weir length more than compensates for this.

    Much research has been performed into the discharge-head relationships of labyrinth weirs, with those developed by Tullis et al. [i] being widely accepted. These use a standard weir equation based on total head, with a variable coefficient of discharge based on a function of labyrinth angle and H/P, where H is the total upstream head, and P is the depth of weir crest relative to the upstream bed level. The labyrinth angle (α) is that subtended by the weir with the direction of flow, with a linear weir being represented by the case α=90˚.

    As the upstream head increases, the labyrinth weir becomes less efficient, hence the coefficient of discharge decreases. Although the equations are not verified for H/P > 0.9, the coefficient of discharge (c ) values must logically approach those of a linear weir for large H; the values of c are therefore extrapolated to this end for large H.

    For drowned weir flow, the weir begins to act as a linear weir, with appropriate drowning reduction factor applied to the free flow weir equation. Two formulations of the drowning factor are available - the Villemonte formulation, which applies a reduction factor from when the downstream water level exceeds crest level, and the standard Flood Modeller drowning factor, which applies once the downstream to upstream head ratio exceeds the predefined modular limit. Research by Tullis et al .(2007)[ii] suggests the Villemonte relationship tends to overestimate the upstream head for drowned flow; using the same findings, the Flood Modeller relationship, if anything, may underpredict the upstream head.

    Weir Equations

    Mode 0 - dry crest

    Conditions:

    h1≤0

    h2≤0

    Equation:

    Q=0

    Mode 3 - free weir flow

    Conditions:

    h1>0

    h2<mh1

    Equation:

    RiverNodesimageslabyimage002.gif

    Mode 4 - drowned weir flow

    Conditions:

    h1>0

    h2≥mh1

    Equation:

    RiverNodesimageslabyimage004.gif

    RiverNodesimageslabyimage006.gif
    (Villemonte; used if m≤0)


    RiverNodesimageslabyimage010.gif


    (alternative formulation; used if m>0)

    Where

    Q - discharge over weir (m3s-1)

    cd - coefficient of discharge; calculated as a function of H1/P and α. See Tullis et al. (1995) for full formulation.

    L - effective length of weir (m)

    g - acceleration due to gravity (=9.81ms-2)

    H1 - total upstream head, relative to weir crest (m)

    P - depth of weir crest above upstream bed (m)

    fdr - drowned flow reduction factor

    h1 - upstream water level above weir crest (m)

    h2 - downstream water level above weir crest (m)

    Weir geometry

    RiverNodesimageslabyimage012.jpg

    Note: The calculated values of cd are heavily dependent on the ratio H/P as well as the labyrinth weir angle α, so it is imperative that these values are entered correctly.

    The effective length of the weir, L, is defined as the total length along the weir crest.

    If the effective length is not entered by the user, it may be calculated from the constituent components, namely

    L1 - length along crest of one arm of the labyrinth (m), or B - length of labyrinth in the direction of flow (m).

    N - number of labyrinth cycles - need not be an integer, but normally should be a multiple of one half.

    D - width of labyrinth apex exterior (m), or A – width of labyrinth apex interior (m)

    t - thickness of labyrinth weir (m)

    W - breadth of channel at weir section (e.g. from left to right bank) (m).
    NB Thickness and apex widths may both be zero; positive values must be entered for the other components.

    If the upstream and/or downstream nodes of a labyrinth weir are not connected directly to a river (or other channel) section, the use of remote nodes is highly recommended. This allows Flood Modeller to calculate an area, and hence velocity, in order to calculate the velocity and total heads. If remote nodes are not specified in such instances, the upstream flow area will be estimated using the channel breadth, W , and depth of weir above bed, P.

    Alternatively, the velocity head may be ignored by selecting the "Use static head" option. This may be particularly relevant when the labyrinth weir is being used to model discharge over a spillway from a reservoir, for instance.

    Additional Options

    1. Drowned flow formulation (see above) - the option to select between the Villemonte and alternative formulations of drowned flow reduction factor is governed by the choice of modular limit (set to zero for Villemonte; between 0 and 1 for the alternative formulation).
    2. The "Use static head" option may be used to force the weir equation to use static head in preference to total head (see above).
    3. It is occasionally possible that no solution is possible given the above formulation, being based on total head, which has a minimum value > 0. It may in such cases be necessary to reduce the calculated value of cd by setting the lower limit of cd (cdlim) to be lower than Lsinα.

    Other applications

    Oblique weirs - an oblique weir can be thought of a special case of labyrinth weir with n=½.

    Horseshoe weirs - although not specifically validated by the research of Tullis et al. (1995), a similar principle applies, in that the effective weir length is longer than the channel breadth, but behaves more like a linear weir as the water level increases. It is suggested to enter the effective length of the weir, L , the breadth of channel, W , and labyrinth angle may be approximated by L sinα= W .

    The unit state output for a labyrinth weir is the drowned flow reduction factor.


    [i] Tullis, J.P., Amanian, N. and Waldron, D. (1995), Design of Labyrinth Spillways, J Hyd Eng 121 3, pp247-255

    [ii] Tullis, B.P., Young, J.C. and Chandler, M.A. (2007), Head-Discharge Relationship for Submerged Labyrinth Weirs, J Hyd Eng 133 3, pp248-254

    Datafile Format

    Line 1 - Keyword 'LABYRINTH WEIR' [comment]. NB Only first nine characters read.

    Line 2 - Label1, Label2, [Label3], [Label4]

    Line 3 - P1, alpha, W, N, B, A, t, zc, L

    Line 4 - ccf, m, cdlim, L1, D, shflag

    Example

    LABYRINTH WEIR    Avon Spillway
    LabyU       LabyD
         3.010      27.5   135.360    10.000       0.0       0.0       0.0       0.0  
         1.000     0.700     0.000    13.230              STATIC

    [1] Remote labels are strongly recommended if the adjoining unit is not a channel section

    [2] Only used if effective labyrinth weir length is not specified

    [3] L1 may be used as an alternative to B (and vice versa )

    [4] D may be used as an alternative to A (and vice versa )

    [5] If total labyrinth length is not specified, then the length may be derived from the constituent components


    Was this article helpful?

    What's Next
    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.