Conduit Channel Conveyance
    • 23 Aug 2022
    • 1 Minute to read

    Conduit Channel Conveyance


    Article summary

    Conduit channel conveyance can be calculated using Manning's equation or the Colebrook White equation.

    Manning's Equation

     

    k2 = A2 R4/3 / n2

    (1)

    where:

    n = Manning's roughness coefficient

    R = hydraulic radius = (A/P)

    The Colebrook White Equation

     

    k2 = 8 g R A2 / f

    (2)

    where f is a solution to the equation:

    1/Öf = -2log10{(n / 14.83R) + (2.52 / Re Öf)}

    (3)

    and:

    Re = Reynolds number

    R = hydraulic radius = (A/P)

    P = wetted perimeter


    Was this article helpful?

    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.
    ESC

    Eddy AI, facilitating knowledge discovery through conversational intelligence