1D urban - 2D FM linked models

Prev Next

Building a stable and robust 1D urban linked model

Flood Modeller’s 1D urban solver allows you to model sewer networks and other drainage systems within the powerful user interface. It can be dynamically linked to the 1D river solver to model channels, or its 2D solver to model surface water flow, to model the interaction with and the impact on the drainage network.

This article provides all the information you need to set up all the checks that should be performed when an existing 1D urban network is linked to 2D model. This is to ensure all urban and 2D parameters are set to enable a stable and robust linked model in which flow can be exchanged in both directions between the different components.

The article details which parameters might need to be adjusted and explains how the model diagnostic information can help you set up a stable and correct linked model. When linking to other 1D urban node types, e.g. outfalls, you only consider a subset of the parameters detailed in the article.

The table below provides a summary of the key 1D urban parameters to consider:

ParameterCheck
Ponded areasPonded area property of 1D urban junction nodes should be set equal to area of 1D-2D linking element (e.g. 3m x 3m square element area =                        or 2D grid cell area – whichever is bigger) 1D urban model settings; tick option to “Allow Ponding”.
Ground elevations at urban nodes2D ground elevation at locations of 1D-2D linking elements should equal combination of 1D junction invert level and maximum depth parameters.
Options to address discrepancies are:
  • Adjust 1D junction parameters
  • Adjust 2D topography (add local topographic features) 
  • Tick auto-adjust DEM option in 2D model interface > 1D urban links tab
Dynamic Wave routing2-way linking between 1D urban and 2D components requires the following routing options to be selected in 1D urban model settings:
  • General tab: Routing Model = Dynamic Wave
  • Dynamic Wave tab: Untick “Use Variable Time Steps”
Surcharged depthIf ponded area is set to non-zero, e.g. for linked junctions, then surcharge depth is ignored. Thus, only check is to review any junctions not linked to 2D to ensure appropriate surcharge depth values set for integrated system.
1D urban link elementsIf linked model system is failing due to instabilities, then check size / shape of linking elements. Recreating links to cover larger area can aid stability (note 1D junction ponded areas will also have to increase to match new link shape sizes).
Coefficient of discharge assigned to link elementsCoefficient of discharge (cd) defines link flows from 2D domain into 1D junction (as weir type flow). This can be adjusted to aid calibration - edit “cd” attribute in link element shapefile.
Note: Weir breadth represented by perimeter of link element shape. If shape size is increased (see above) then weir flow will increase, thus cd may have to be adjusted to compensate.

The following sections provide more detailed explanations for each of the above items.

Ponded Areas

The ponded area parameter in a junction (manhole) node represents the area occupied by ponded water atop the junction after flooding occurs (sq. feet or sq. metres). If the Allow Ponding analysis option in model settings is turned on, a non-zero value of this parameter will allow ponded water to be stored and subsequently returned to the drainage system when capacity exists.

In a standalone 1D urban model, the ponded area parameter for a junction could be set to a substantial area to enable large spill volumes to be handled. However, when a junction is connected to a 2D model, the area set aside for ponding water is now handled by the 2D model, so these large areas are no longer appropriate. Instead there are two options for ponded area that will influence how a linked model will perform:

  1. The ponded area is set to match the area of the 2D linking element. This enables the link to operate in both directions, i.e. flow out of urban onto the 2D floodplain and 2D flows into the urban junction.
    • If the 2D linking element is a polygon then the expected ponded area should be the area of these elements, e.g. the default is                                                 (or                            for US units). However, if the linking element spans across multiple computational grid squares then the 2D solver might interpret the area as a larger value.
    • If the 2D linking element is a polyline then the 2D solver will calculate the expected ponded area as the sum of all computational grid squares beneath the polyline.
    • If the linking element is a point, then the 2D solver will expect the ponded area to be the area of a computational grid square.

If there is a significant discrepancy between a junction ponded area and the expected area calculated from the associated 2D link element, then the 2D solver will report a warning in the 2D diagnostics to enable the discrepancy to easily be corrected. Thus, it may be necessary to re-start a simulation one or more times to ascertain and correct all diagnostic warning messages.

Typical ponded area warning messages is as follows: 

"WARNING: Area of linked cells = ; Ponded Area of 1D Urban node = . The areas should be approximately equal"

  1. The ponded area is set to zero. In this case the 2D solver will be unable to transfer water into the 1D urban network. However, water can still spill from linked urban junctions onto the 2D domain. 

Note: Ponded areas are only a factor for linked 1D urban junction nodes. Other node types, e.g. outfalls, do not possess this property. 

Ground elevations at urban nodes

The ground level at a 1D urban junction is calculated from the addition of the invert elevation and the maximum depth values. Maximum depth at the junction is the distance from the invert to the ground surface (feet or metres). If zero, then the distance from the invert to the top of the highest connecting link will be used to ascertain ground level.

When linking to a 2D model, the ground level assumed by the 1D urban solver from these parameters should align with the ground level used by the 2D solver at the associated 2D linking element. The 2D solver defines a computational ground grid from all entered topography data. So, the cells of this grid underlying a 2D linking element will define the level at a junction within the 2D model.

Note that where the 2D link shape (polygon polyline or point) and size means that it sits across multiple computational cells then all these cells should have an elevation that matches the 1D urban junction ground level.

If the 1D urban ground level and associated 2D level differ significantly then a warning will be reported in the 2D diagnostics file (2D log file). A typical warning is as follows:

“WARNING: 2D Ground elevation:                   differs significantly from 1D urban link level:                  . This may cause unpredictable results”

The presence of this type of level difference can cause model instability and/or adversely affect results. There are three options to address this: 

  1. Edit junction properties changing the invert level or maximum depth value to ensure the sum of these match the local 2D ground elevation.
  2. Add extra 2D topographic features to the 2D model to adjust ground levels locally around the linked junctions to match levels specified by junction properties.
  3. On the 2D model interface > 1D urban tab - tick the option to auto-adjust 2D DEM if it is lower than 1D link surface elevation. This setting also requires a threshold to be set for discrepancy size. Set this to a small, non-zero value to ensure all significant discrepancies are handled automatically by the 2D solver during a simulation (set to negative if the 2D DEM is predominantly above the linked 1D urban junction surface levels).

Dynamic Wave routing

A 1D urban model can only successfully link to a 1D river or 2D model if the urban routing model is set to Dynamic Wave. This setting is specified in the 1D urban model settings window, which is accessed by right-clicking on the relevant network listed in the 1D Urban Networks section of the Project panel. Routing models are selected on the General tab of the model settings window, as shown below.

In addition to this setting, the Dynamic Wave tab of the model settings window must also be checked to ensure the variable time steps option is not selected. This option is not compatible with dynamic linking to 1D river or 2D models.

Surcharged depth

The surcharged depth parameter of 1D junction nodes represents an additional depth of water beyond the maximum depth that is allowed before the junction floods (feet or metres). This parameter can be used to simulate bolted manhole covers or force main connections.

This parameter will not affect the performance of links to 1D river or 2D models as the 1D urban solver ignores surcharge depth when ponding is activated, i.e. ponding area is nonzero. Since ponding area is a required parameter for linking to work, surcharge depths specified for linked junctions will always be ignored.

However, a review of surcharge depths may still be beneficial when linking a 1D urban model into an integrated system. Junction nodes initially not linked to any 1D river or 2D model will still be affected by their surcharge depth value and this may not be appropriate in the integrated model.

Note: Surcharge depth is only specified for linked 1D urban junction nodes. Other node types, e.g. outfalls, do not possess this property.

1D urban link elements

In some scenarios, all previous discussed 1D urban parameters could be set appropriately for a 1D-2D linked model, but the resulting simulations still fail due to model instabilities. If a model fails as the linked 1D junctions start to surcharge onto the 2D domain, then it could be too much water is being added in one timestep to the 2D grid cells connected to the linking element. This may be fixed by increasing the “footprint” of the 2D linking elements, so they extend across multiple 2D computational grid cells. Thus, inflow volumes will be spread across multiple 2D cells, which should improve the model stability.

The simplest method to change the size of the 2D linking elements is to go back to the 1D Urban / 2D linking tool and recreate them as a new linking shapefile. Utilise the advanced settings in this tool to increase the size of the linking elements, compared to the previous iteration:

  • If the previous link file used shapefile points, then change to a line or square shape type
  • If the previous link file already used lines or squares, then increase the element dimension (or change from line to square type)

Note: If the size of the linking elements is increased then the ponded areas of the linked 1D junctions will need to be increased to match. 

Coefficient of discharge assigned to link elements

The exchange of flow from a 2D domain to a 1D urban junction utilises a weir equation to determine (free) flow rates. The magnitude of flow from this equation is dependent on an effective breadth, which will be represented by the perimeter of the 1D-2D linking element, i.e. the perimeter of the specified ponded area (as described above; junction ponded area should equal the area of the linking element).

For some models it may be necessary to increase the size of the linking elements to improve model stability, i.e. so they overlay multiple 2D computational grid cells. Thus, the perimeter of these areas will increase and consequently the calculated free flows from 2D into 1D urban components will increase.

This may adversely affect the calibration of the integrated model. In this case, action may be required to counteract the increase in calculated exchange flows. The weir equation includes a coefficient of discharge parameter (“cd”). This can be set globally for all links or individually per link. Usually it is sufficient to use the default setting for cd. However, the value is not fixed and so there is scope to adjust this value to aid model calibration.

The value can be adjusted for each 1D-2D link by editing the “cd” attribute in the link element shapefile. There is also a global setting defined in the 2D model interface (note this will only be applied if a no data cd value, , is defined in the shapefile for a link element).